On one sheet of 8-1/2" x 11" paper, combine the curtain wall details in Brand, pp.126-129, and draw a single detailed wall section through a typical floor and roof. Use same scale (3"=1'-0", or 1/4 full size).
Carefully label all construction items, as in Brand.
Notes:
- The floor detail on pp. 128-129 is cut through the vertical mullion; your detailed section should be cut through the glass, as in the parapet detail.
- Add in a schematic representation of a low-profile fan coil (heating, cooling) unit below the "vision panel" (transparent glass lite) on the typical floor. See Architectural Graphic Standards for details.
- Use spandrel glass to hide the structure of the roof and floor.
- Include the suspended ceiling under the roof and floor slabs.
- Large scale mullion/rail details from Brand and Allen are attached for reference only. Note that the detail in Allen does not indicate venting and pressure equalization.
last updated: 6 Nov. 1998
|
|